
Meco DIT-99C Insulation Tester
PRODUCT FEATURES:
- Different Models From 100v to 1000v
- 3.5 Digt LCD Display
- Single Person Press Button Operation
- Carying case.
DOWNLOAD PDF FILE
Related Products
-
KEW 6010B Multi Function Tester
PRODUCT FEATURES :
- Insulation Resistance Testing:500/1000V, 20/200MΩ 1mA Rated Test Current
- RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
- Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
- Continuity:20/200Ω 200mA Test Current
- Test of a large kind of RCD’s:Standard, Selective, AC and A(DC sensitive breakers)
- Uc(Contact Voltage): 100V
- Designed to IEC 61010-1, IEC 61557
- Data Memory:300 measured results
- The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.
- INSULATION TEST RANGE: 500/1000V
- INSULATION MEASURING RANGE: 20/200MΩ
- CONTINUITY MEASUREMENT
- LOOP IMPEDANCE TESTING
- RCD TESTING
- UC TESTING
-
You've just added this product to the cart:
HIOKI IR4056 / IR4057 Digital Insulation Tester
Read MoreQuick ViewHIOKI IR4056 / IR4057 Digital Insulation Tester
PRODUCT FEATURES:
- 5-range testing voltage of 50 V/100 M to 1000 V/4000 M
- Stable & medium – speed digital readings, 0.8 second response time of PASS/FAIL decisions
- Drop proof onto concrete from 1m (3.28 feet)
- Bright LED, luminous LCD, test lead with bright LED lamp to illuminate near hand ( Also available in the IR4056-21)
- Continuity check via 200 mA testing
- Built in AC/DC voltage meter, useful for testing solar power generation systems and electric vehicles .
DOWNLOAD PDF FILE
-
KYORITSU 6011A MULTI-FUNCTION METER
PRODUCT FEATURES :
- Live circuit and wiring connection check LED’s
- Triple ranges insulation tests at 250,500 and 1000V.
- Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
- Phase angle selection on RCD ranges
- Polarity switch for continuity tests
- Auto-null facility for continuity tests
- Earth probe for loop impedance testing on extraneous metal work
- Contact Voltage Reading
- Test of a large kind of RCD’s: Standard, Selective, AC and A (DC sensitive breakers)
- Continuity Testing:20/200/2000Ω (Autoranging)
- Insulation Testing:250V 500V 1000V DC 20/200MΩ (Autoranging)
- Loop Impedance Testing:Voltage Measuring Range 100 – 250V AC [50Hz] , Impedance Ranges 20/200/2000Ω . Nominal Test Current 25A (20Ω range) 15mA (200Ω range) 15mA(2000Ω range)
- PSC Testing: Rated Voltage: 230V AC
- PSC Ranges: 200A (15mA Test Current),2000A (25A Test Current), 20kA (25A Test Current)
- RCD Testing: Rated Voltage: 230V AC
- Trip Current Settings RCD × 1/2 10,30,100,300,500,1000mA < RCD × 1 : 10,30,100,300,500,1000mA, RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A)
- Trip Current Duration:RCD × 1/2 × 1: 2000ms RCD fast: 50ms.
- INSULATION TEST RANGE: 250/500/1000V DC
- INSULATION MEASURING RANGE: 20/200MΩ
- CONTINUITY TESTING
- LOOP IMPEDANCE TESTING
- RCD TESTING
- PSC TESTING
-
Fluke 1587 Insulation Multimeter
PRODUCT FEATURES :
- Fluke 1587 is a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit.
- Insulation test voltages: 50V/100V/250V/500/1000V , Insulation test Resistance : 0.01 MΩ to 2.0 GΩ
- Auto discharge of capacitive voltage
- Insulation test smoothing reading
- Frequency: Maximum frequency 100 kHz
- Capacitance: Maximum capacitance 9,999 µF
- Diode test: Range/Resolution 6 V / 1 mV
- Temperature Measurement: -40.0°C to 537°C
- CAT III 1000V, CAT IV 600V measurement category
- Low pass filter (for work on VSD’s)
- AC/DC Voltage: Maximum voltage 1000 V
- DC millivolts
- AC/DC milliamps: Maximum amps 400 mA
- Resistance: (0.1 Ω to 50 MΩ)
- Continuity
- INSULATION TEST RANGE: 50V, 100V, 250V, 500V, 1000V
- INSULATION MEASURING RANGE: 0.01MΩ TO 2GΩ
-
Rishabh Rish insu 10
PRODUCT FEATURES :
- suitable for :- Measurement of the insulation resistance on electrically dead equipment and systems with test voltages up to 1000V.
- Test Voltages 50V/ 100V/ 250V/ 500V/ 1000V
- Hands-free continuity testing
- Insulation Resistance Measurement
- Automatic discharge for capacitive circuits after test Measurement
- Pre-selectable measurement time for Insulation Resistance Measurement
- Low Resistances Measurement (0.01Ohm… 99.9 Ohm)
- STOP WATCH
- LIVE CIRCUIT DETECTION
- STORAGE OF MIN/MAX VALUES
- BLOWN FUSE INDICATION