CEM- DT- 903 Socket Polarity and Earth Leakage Tester
PRODUCT FEATURES:
- The appearance of the socket design, greatly expanded the scope of its Without power to support the use of more convenientOperating
- Temperature: 0 C – 40 C,
- The level of contamination: 2
- By type of protection:IP40 .
DOWNLOAD PDF FILE
-
HIOKI 3283-20 Clamp On Leak Hitester
PRODUCT FEATURES:
- measure leak current using highly sensitive 10uA resolution (at 10.00 mA range)
- Indicate 50/60 Hz leak current components with the filtering function
- Monitor leak current conditions in combination with a Memory HiCorder (monitor output, Model 3283 only)
- 3283-20: EN 61010-2-032:2012 Type A to measure uninsulated hazardous live conductors such as busbars .
DOWNLOAD PDF FILE
-
HIOKI 3293-50 Clamp On Leak Hitester
PRODUCT FEATURES:
- Measure for leakage current and load all with the same device
- Innovative flip clamp design
- Flip display to see measurement readings from any angle
- 1mA to 1000A accuracy guaranteed
- 6 ranges and bar graph display
- Measure and display only the leakage current of commercial frequency components using the filter function .
DOWNLOAD PDF FILE
-
MOTWANI DCM-10A Digital Clamp Meter
PRODUCT FEATURES:
- 0.01 mA resolution for measuring earth leakage currents.
- 300 A range for standard current
- Measurements, Analogue Bargraph Display
- For trending. Pocket sized and lightweight
- Jaw size 40mm
DOWNLOAD PDF FILE
-
LUTRON DL-6054 ACA Leakage Tester
PRODUCT FEATURES :
- High precision AC mA measurement, it is useful for AC mA leakage current measurement.
- Measure AC mA on the inductive conductor.
- Miniature type, easy to carry out & operation.
- High precision for low ACA leakage current measurement.
- Built-in DATA HOLD function.
- Crystal time base, high quality.
- LCD display allows clear readout-out even at high ambient light level.
- LSI circuit provides high reliability and durability.
- Overload protection circuit is provided for all range.
- Design to meet IEC 1010 safety requirement.
- Compact, light weight and excellent operation.
- Measurement:200 AC mA/20ACA/200A
- Overload Circuit Protection : 300 ACA max. ( within 1 minute for 20A, 200A range ).
- Zero adjustment Automatic adjustment.
- Over input Display shows ‘1’.
- Sampling Time Approx. 0.4 second.
- Operating Temp. 0 to 50 ℃ ( 32 to 122 ℉ ).
- Operating Humidity Less than 80% RH.
-
Kyoritsu 2412 Leakage Clamp Tester
PRODUCT FEATURES :
- Kyoritsu 2412 is specially designed for Leakage Current Measurement.
- AC A (50/60Hz): 20/200mA/2/20/200/500A
- AC A (WIDE): 20/200mA/2/20/200/500A
- AC Voltage: 600V
- Resistance: 200Ω
- Conductor size: Ø40mm max.
- Frequency response: 40 – 400Hz
- Effect of external stray magnetic field φ15mm 100A – 10mA AC max.
- Output Recorder : DC200mV against the maximum value of each range (500A range is 50mV)
- Power source: 6F22 (9V) × 1 or AC Adaptor
-
Kyoritsu 2413F Leakage Tester
PRODUCT FEATURES :
- Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement. Frequency filter switch to eliminate the effect of harmonics.
- Output terminal.
- Resolution 0.1mA.
- AC A (50/60Hz): 200mA/2/20/200A/1000A
- AC A (WIDE): 200mA/2/20/200/1000A
- Conductor size: Ø68mm max.
- Frequency response: 40Hz – 1kHz
- Output Waveform : AC200mV against the maximum value of each range (1000A range is 100mV)
- Recorder : DC200mV against the maximum value of each range (1000A range is 100mV)
-
Kyoritsu 2413R Leakage Clamp Tester
PRODUCT FEATURES :
- Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
- True RMS enables an accurate measurement for distorted waveforms.
- Measurement from mA up to AC 1000A.
- Frequency filter switch to eliminate the effect of the harmonics.
- 2 way analogue output terminal.
- AC A (50/60Hz): 200mA/2/20/200/1000A
- AC A (WIDE): 200mA/2/20/200/1000A
- Crest factor: 3.0 or less
- Conductor size: Ø68mm max.
- Frequency response: 40Hz – 1kHz
- Output Waveform : AC200mV against the maximum value of each range (1000A range is 100mV) , Recorder : DC200mV against the maximum value of each range (1000A range is 100mV)
-
Kyoritsu 2431 Leakage Clamp Tester
PRODUCT FEATURES :
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges 20mA/200mA/200A.
- Rotary switch for easy one finger power-on and range selection.
- AC A (50/60Hz): 20/200mA/200A
- AC A (WIDE): 20/200mA/200A
- Conductor size: Ø24mm max.
- Frequency response: 40 – 400Hz
- Effect of external stray magnetic field φ15mm 100A: 10mA AC max.
- Safety Standard: IEC 61010-1 CAT III 300V , IEC 61010-2-032
-
Kyoritsu 2432 Leakage Clamp Tester
PRODUCT FEATURES :
- High Sensitive Model
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges:4mA/40mA/100A.
- AC A (50/60Hz): 4/40mA/100A
- AC A (WIDE): 4/40mA/100A
- Maximum circuit voltage: 600V AC/DC (between line/neutral), 600V AC/DC(between line/neutral)
- Conductor size: Ø40mm max.
- Frequency response:20Hz – 1kHz(40Hz -1kHz:100A)
- Effect of External Stray Magnetic Field: 2mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC.
- Response Time: Approx. 2 seconds
-
Kyoritsu 2433 Leakage Clamp Tester
PRODUCT FEATURES :
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges:40mA/400mA/400A.
- AC A (50/60Hz): 40/400mA/400A
- AC A (WIDE): 40/400mA/400A
- Maximum circuit voltage: 600V AC/DC (between line/neutral), 300V AC/DC (against earth)
- Conductor size: Ø40mm max.
- Frequency response:20Hz – 1kHz(40Hz -1kHz:400A)
- Response Time: Approx. 2 seconds
- Effect of External Stray Magnetic Field: 10mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC.
-
Kyoritsu 2433R Leakage Clamp Tester
PRODUCT FEATURES :
- True RMS Measurement.
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges:40mA/400mA/400A.
- AC A (50/60Hz): 40/400mA/400A
- AC A (WIDE): 40/400mA/400A
- Maximum circuit voltage: 600V AC/DC (between line/neutral), 300V AC/DC (against earth)
- Conductor size: Ø40mm max.
- Frequency response: 20Hz – 1kHz[40Hz-1kHz:400A]
- Effect of External Stray Magnetic Field: 10mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC.
- Response Time: Approx. 2 seconds
- Home
- Our ProductsNEW
CATEGORY
CATEGORY
- Electrical Testers
- Clamp On Power Meters
- Breath Alcohol Tester
- Capacitance Meters
- Dial Indicator
- Block Level Meter
- CO2 Analyzer
- Contact Type Thermometers
- Data Loggers
- Coating Thickness Gauge
- EMF Testers
- Force Gauge
- Insulation Testers
- Loop Calibrator
- LUX / UVA-UVB Meters
- Manometer
- Milli/Micro-Ohm Meters
CATEGORY
CATEGORY
CATEGORY
FREE SHIPPING
For all those who like our FB page.FIVE STAR RATING
Rated 5 Star by our customers.ONLINE SUPPORT
Online Support Available.
- About Us
- Contact Us