-
Testo 184 H1 Air Humidity And Temperature
PRODUCT FEATURES :
- With the air humidity and temperature data logger testo 184 H1, you monitor the transport of sensitive goods such as pharmaceuticals, foods or electronics or art, over an unlimited period.
- Unlimited operating time
- All in one data logger: PDF measurement data, configuration file and instruction manual
- APPLICATIONS:- – – – – – – –
- Monitoring and documentation of temperature, humidity and shock in food logistics.
- Monitoring and documentation of temperature and humidity during the transport of flowers
- Monitoring and documentation of temperature, humidity and shock in logistic services of all kinds
- Monitoring and documentation of temperature, humidity and shock in pharmaceutical logistics.
- Temperature – NTC: -20 to +70 °C
- Accuracy: ±0.5 °C (0 to +70 °C)
- Resolution: 0.1 °C
- Humidity – Capacitive: 0 to +100 %RH
- Resolution: 0.1 %RH
- Memory: 64,000 measuring values
- Battery life: 500 days (at +25 °C and 15 mins measurement rate).
- Immediate creation of a PDF report directly after connection to a computer
- Monitoring transport in compliance with GxP, 21 CFR Part 11 and HACCP.
- MEASURING RANGE: -20 TO +70 °C
- DATA LOGGER FOR TEMPERATURE AND HUMIDITY & OPERATING DURATION: UNLIMITED
-
HI 9146-04
PRODUCT FEATURES :
- Water Resistant,microprocessor-based, Dissolved oxygen meter with automatic calibration and Temperature calibration compensation.
- extended Altitude & Salinity compensation.
- Range: 02,Saturation 02 & Temperature.
- Weighs 500gms approximately.
-
HI 2400
PRODUCT FEATURES :
- For Professional DO Monitoring.
- Essential instrument for testing Pharmaceutical and food Products as well as monitoring in water treatment plants.
- allows measurement compensation both for altitude and salinity factors.
- Supplied with polrographic sensors which measures the current generated by the reaction of 92 with Ag for enhanced stability.
-
FLUKE T5-1000 Voltage,Continuity & Current Tester
PRODUCT FEATURES :
- Automatically measures volts ac and volts dc with precise digital resolution
- Displays resistance to 1000Ω
- Easy and accurate OpenJaw™ current measurement
- Continuity beeper
- Compact design with neat probe storage
- Rugged enough to withstand a 10-foot (3m) drop
- Detachable SlimReach™ probe tips are customized for national electrical standards
- Test leads accept Fluke accessory test clips
- Available in 600V and 1000V models
- Can stay connected much longer than solenoid type tester
- Auto off mode to conserve battery life
- Optional holster attaches to a belt and neatly stows test leads
- Continuity beeper
- Threshold: On at <25 Ω, off at >400 Ω
- Volts indicator LED
- Threshold:Guaranteed on by 30V ac
- DISPLAYS RESISTANCE: 1000Ω
- CONTINUITY BEEPER: <25 Ω, OFF AT >400 Ω
- VOLTS INDICATOR LED: 30V AC
-
FLUKE T5-600 Voltage,Continuity & Current Tester
PRODUCT FEATURES :
- Automatically measures volts ac and volts dc with precise digital resolution
- Displays resistance to 1000Ω
- Easy and accurate OpenJaw™ current measurement
- Continuity beeper
- Compact design with neat probe storage
- Rugged enough to withstand a 10-foot (3m) drop
- Detachable SlimReach™ probe tips are customized for national electrical standards
- Test leads accept Fluke accessory test clips
- 600V model
- Can stay connected much longer than solenoid type tester
- Auto off mode to conserve battery life
- Optional holster attaches to a belt and neatly stows test leads
- Jaw opening: 12.9 mm (0.5 in)
- Current range ac rms: 0 to 100.0 A
- Voltage range ac: 0 to 600 V
- Voltage range dc: 0 to 600 V
- Resistance range: 0 to 1000 Ω
- Volts indicator LED threshold Guaranteed on by 30 V ac
- Continuity beeper threshold On at <25 Ω, off at >400 Ω
- Operating Temperature: -10 °C to 50 °C
- Storage Temperature: -30 °C to 60 °C
- Humidity (Without Condensation) 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
- 0 % to 45 % (40 °C to 50 °C)
- Operating Altitude: 2000 meters max
- Temperature Coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
- Overvoltage category CAT III 600 V ac/dc (EN61010-1)
- VOLTAGE AC/DC : 0 TO 600 V
- CONTINUITY BEEPER , RESISTANCE , TEMPERATURE , HUMIDITY
-
KYORITSU 8031 Phase Indicator
PRODUCT FEATURES :
- Digital Phase Indicator with open phase checker.
- Phase indicator designed to check the presence of open phase and also the phase sequence by LED and buzzer at the same time.
- Small, lightweight, and portable.
- Operational voltage: 110 – 600V AC
- Time limit for continuous: >500V: within 5 minutes
- Frequency response: 50/60Hz
- Applicable standards: IEC 61010-1 CAT III 600V Pollution degree 2
- Withstand Voltage: 5550V AC for 1 minute
- OPERATIONAL VOLTAGE: 110~600V AC
- 3 PHASE POWER SOURCE
- FREQUENCY RESPONSE: 50HZ/60HZ
-
LUTRON DL-6054 ACA Leakage Tester
PRODUCT FEATURES :
- High precision AC mA measurement, it is useful for AC mA leakage current measurement.
- Measure AC mA on the inductive conductor.
- Miniature type, easy to carry out & operation.
- High precision for low ACA leakage current measurement.
- Built-in DATA HOLD function.
- Crystal time base, high quality.
- LCD display allows clear readout-out even at high ambient light level.
- LSI circuit provides high reliability and durability.
- Overload protection circuit is provided for all range.
- Design to meet IEC 1010 safety requirement.
- Compact, light weight and excellent operation.
- Measurement:200 AC mA/20ACA/200A
- Overload Circuit Protection : 300 ACA max. ( within 1 minute for 20A, 200A range ).
- Zero adjustment Automatic adjustment.
- Over input Display shows ‘1’.
- Sampling Time Approx. 0.4 second.
- Operating Temp. 0 to 50 ℃ ( 32 to 122 ℉ ).
- Operating Humidity Less than 80% RH.
-
Kyoritsu 2412 Leakage Clamp Tester
PRODUCT FEATURES :
- Kyoritsu 2412 is specially designed for Leakage Current Measurement.
- AC A (50/60Hz): 20/200mA/2/20/200/500A
- AC A (WIDE): 20/200mA/2/20/200/500A
- AC Voltage: 600V
- Resistance: 200Ω
- Conductor size: Ø40mm max.
- Frequency response: 40 – 400Hz
- Effect of external stray magnetic field φ15mm 100A – 10mA AC max.
- Output Recorder : DC200mV against the maximum value of each range (500A range is 50mV)
- Power source: 6F22 (9V) × 1 or AC Adaptor
-
Kyoritsu 2413F Leakage Tester
PRODUCT FEATURES :
- Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement. Frequency filter switch to eliminate the effect of harmonics.
- Output terminal.
- Resolution 0.1mA.
- AC A (50/60Hz): 200mA/2/20/200A/1000A
- AC A (WIDE): 200mA/2/20/200/1000A
- Conductor size: Ø68mm max.
- Frequency response: 40Hz – 1kHz
- Output Waveform : AC200mV against the maximum value of each range (1000A range is 100mV)
- Recorder : DC200mV against the maximum value of each range (1000A range is 100mV)
-
Kyoritsu 2413R Leakage Clamp Tester
PRODUCT FEATURES :
- Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
- True RMS enables an accurate measurement for distorted waveforms.
- Measurement from mA up to AC 1000A.
- Frequency filter switch to eliminate the effect of the harmonics.
- 2 way analogue output terminal.
- AC A (50/60Hz): 200mA/2/20/200/1000A
- AC A (WIDE): 200mA/2/20/200/1000A
- Crest factor: 3.0 or less
- Conductor size: Ø68mm max.
- Frequency response: 40Hz – 1kHz
- Output Waveform : AC200mV against the maximum value of each range (1000A range is 100mV) , Recorder : DC200mV against the maximum value of each range (1000A range is 100mV)
-
Kyoritsu 2431 Leakage Clamp Tester
PRODUCT FEATURES :
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges 20mA/200mA/200A.
- Rotary switch for easy one finger power-on and range selection.
- AC A (50/60Hz): 20/200mA/200A
- AC A (WIDE): 20/200mA/200A
- Conductor size: Ø24mm max.
- Frequency response: 40 – 400Hz
- Effect of external stray magnetic field φ15mm 100A: 10mA AC max.
- Safety Standard: IEC 61010-1 CAT III 300V , IEC 61010-2-032
-
Kyoritsu 2432 Leakage Clamp Tester
PRODUCT FEATURES :
- High Sensitive Model
- Frequency Selector Switch to eliminate the effect of harmonics.
- Three AC current ranges:4mA/40mA/100A.
- AC A (50/60Hz): 4/40mA/100A
- AC A (WIDE): 4/40mA/100A
- Maximum circuit voltage: 600V AC/DC (between line/neutral), 600V AC/DC(between line/neutral)
- Conductor size: Ø40mm max.
- Frequency response:20Hz – 1kHz(40Hz -1kHz:100A)
- Effect of External Stray Magnetic Field: 2mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC.
- Response Time: Approx. 2 seconds
- Home
- Our ProductsNEW
CATEGORY
CATEGORY
- Electrical Testers
- Clamp On Power Meters
- Breath Alcohol Tester
- Capacitance Meters
- Dial Indicator
- Block Level Meter
- CO2 Analyzer
- Contact Type Thermometers
- Data Loggers
- Coating Thickness Gauge
- EMF Testers
- Force Gauge
- Insulation Testers
- Loop Calibrator
- LUX / UVA-UVB Meters
- Manometer
- Milli/Micro-Ohm Meters
CATEGORY
CATEGORY
CATEGORY
- About Us
- Contact Us











